Salisbury 4-Way Electrical Grounding Set

Be the first to review this product

Salisbury Electrical Grounding Set is excellent for the grounding of a 3 phase system.

Availability: In stock

$880.00
Macron Safety

Description

Details

The Salisbury Electrical Grounding Set facilitates the application of multiple grounding jumpers. This set includes four 1.5" aluminum C clamps that feature flat lower jaws and a strain relief sleeve connected to 1/0 yellow ground cable, 10'L to the four-way connector with an 8'L cable to each jumper. It is recommended that four-wire clusters be used for three-phase wire systems. Compliance: Meets ASTM F 855 specifications.

  • Four 1.5" aluminum C clamps with flat lower jaws, strain relief sleeve connected to 1/0 yellow ground cable
  • 10'L to the four-way connector with an 8'L cable to each jumper
  • Type: Insulated Jumper Set
  • Conductor Material: Copper
  • Conductor Size: 1/0 AWG
  • Jacket Material: Thermoplastic Elastomer, Yellow
  • Rating - Current: 21,000 A @ 15 cycles (short circuit withstand), 250A (continuous)
  • Clamp Range - Cable Size: 6 sol CU - 954 mcm ACSR
  • Clamp Range - OD: 1.50 in
  • Clamp Type: C Clamp, Eye, Flat Lower Jaw
  • Contents: (1) Cable, (4) Jumper Clamps , (1) 4-Way Connector, (1) Double Hanger Stud, (1) Contact Stud, (4) Pr. Ferrules
  • Length: 34 ft (total cable)

Additional Info

Additional Info

Model MS-SAL-2680
Set Product as New to Date No
Usually Ships No
Country of Origin USA
Manufacturer Warranty No
Specification No
Manufacturer Macron Safety

Reviews

Write Your Own Review

You're reviewing: Salisbury 4-Way Electrical Grounding Set

Tags

Tags

Other people marked this product with these tags:

Use spaces to separate tags. Use single quotes (') for phrases.

NFPA 70E Training

Any doubts that your company is compliant? Your employees safe?

The 2015 Edition of the NFPA 70E recommendations are in print and take effect January 1, 2015.

Do you and your employees know all of the changes? Have they been implemented into your Electrical Safety Program? Do you have an Electrical Safety Program? Have you had Electrical Safety Training in the last year?

Electrical Safety Compliance Chart for NFPA 70E 2015

If the answer to any of those questions is no, then contact Macron Safety today!

Call 916-905-6535 or contact us to be certain you are in compliance.

Determine the Correct Protection Level, To evaluate Fire Retardant clothing materials in order to measure the heat transferred through the fabric, two values are calculated: Arc Thermal Performance Value (ATPV)...the minimum energy causing the predicted onset of second-degree burns and Heat Attenuation Factor (HAF)...the percentage of total energy of the arc that the fabric prevents from passing through, OSHA requires that each employer must assess the potential hazards in the work environment and determine the appropriate clothing materials using ASTM PS57-97. Always do a hazard assessment. You will need to know electrical system voltage, fault current available, number of phases, Arc time duration, estimated Arc gap, minimum distance from the Arc, and Arc configuration.

Free Duke Power Heat Flux Calculator: For the purpose of calculating heat flux received at a surface some distance from an Electric Arc.