Call 1 (916) 905-6535

Omega Arc Flash Waterproof Hi-Vis Rainwear

Be the first to review this product

8.5 oz/yd2 Advanced Material trilaminate, ePTFE moisture barrier, Arc Resistant (ASTM F1891, NFPA 70E), Flash Fire Resistant (ASTM F2733), HiVis (ANSI 107-2010), Stitched and taped seams, waterproof, breathable, windproff, Made in USA. You can order Jacket only if needed.

Availability: In stock

$566.60

Description

Details

Omega 5000 Series High Visibility Arc Flash Rain Wear

Omega is the first waterproof, breathable outerwear product that combines high visibility worker conspicuity with protection from the thermal hazards associated with an electric arc flash and hydrocarbon flash fires. Intended for use by electric and gas utilities as well as the oil and gas industry, Omega is designed for today's rugged work environment.

  • Removable Winter Liners Available
  • ANSI 107 Class 3 Compliant
  • Fall Protection Access
  • Stain & Soil Resistant
  • Flash Fire Resistant
  • Waterproof
  • Breathable
  • Reduces Worker Heat Stress
  • Lightweight
  • Wind-Proof
  • Designed with Premier Features

Recommended Applications

  • Gas & Electric Utility Transmission & Distribution
  • Telecommunication & CATV Workers
  • Storm Restoration
  • Electrical Maintenance
  • Meter Service
  • Electrical Switching

Specific Material Data

Fabric Omega FR outer Shell; Nomex knit inside
Moisture Barrier PTFE
Finished Weight 9 oz./yd2
Seam Construction 2 needle stitched and sealed with Nomex tape
Color(s) Fluroescent Lime Yellow (FY), Fluorescent Orange (FO)
Reflective Trim 3M Reflective material
Flash Fire Data ASTM F2733 12.3% Body burn 3 second test exposure with 2 cal/cm2 / second heat flux
Electric Arc Data ASTM F1891 FY: Arc Rating (ATPV) 12.3 cal/cm2; HAF 85%; Breakopen 30 cal/cm2
FO: Arc Rating (ATPV 16.5 cal/cm2; HAF 86%; Breakopen 27 cal/cm2
NFPA 70E Navy/FY - HRC 2; NAVY/FO - HRC 2
Visibility Data ANSI 107 Fluorescent Lime Yellow and Fluorescent Orange 5000 Series are ANSI 107 Class 3 Level 2 compliant
Breathable Data ASTM E96, ASTM 1868 ASTM E96 8865 g/m2/24 hrs
ASTM 1868 Test Pending

Ordering Item Information

5503JNFY Navy/Fluorescent yellow waist length jacket, hood-in-collar, nonconductive zipper front with Velcro storm fly front, fall protection access, 2 side entry pockets, tool belt slit with zippers, liner attachments, 3M Scotchlite 2" reflective trim around chest, over shoulder harness and biceps.

5503JNFO Navy/Fluorescent orange waist length jacket, hood-in-collar, nonconductive zipper front with Velcro storm fly front, fall protection access, 2 side entry pockets, tool belt slit with zippers, liner attachments, 3M Scotchlite 2" reflective trim around chest, over shoulder harness and biceps.

5503JNFY106 Navy/Fluorescent yellow 26" length jacket, hood-in-collar, nonconductive zipper front with Velcro storm fly front, fall protection access, 3M Scotchlite 2" reflective trim around chest, over shoulder harness and biceps.

5503JNFO106 Navy/Fluorescent orange 26" length jacket, hood-in-collar, nonconductive zipper front with Velcro storm fly front, fall protection access, 3M Scotchlite 2" reflective trim around chest, over shoulder harness and biceps.

5001TFY106 Fluorescent yellow high back bib style trouser, zipper front with storm fly, quick release suspender self-material system, 2 patch pockets on thighs, reinforced knees, non-conductive leg zippers, 3M Scotchlite 2" reflective trim at calf and ankles.

5001TFO106 Fluorescent orange high back bib style trouser, zipper front with storm fly, quick release suspender self-material system, 2 patch pockets on thighs, reinforced knees, non-conductive leg zippers, 3M Scotchlite 2" reflective trim at calf and ankles.

5001PFY Fluorescent yellow elastic waist pant with drawstring, snap fly front, Klein Tool pocket on right thigh, reinforced knees, nonconductive leg zippers with overfly, 3M Scotchlite 2" reflective trim at calf and ankles.

5001PFO Fluorescent orange elastic waist pant with drawstring, snap fly front, Klein Tool pocket on right thigh, reinforced knees, nonconductive leg zippers with overfly, 3M Scotchlite 2" reflective trim at calf and ankles.

5001TFY Fluorescent yellow bib style trouser with snap fly front, quick release suspender self-material system, Klein Tool pocket on right thigh, reinforced knees, non-conductive leg zippers with overfly, 3M Scotchlite 2" reflective trim at calf and ankles.

5001TFO Fluorescent orange bib style trouser with snap fly front, quick release suspender self-material system, Klein Tool pocket on right thigh, reinforced knees, non-conductive leg zippers with overfly, 3M Scotchlite 2" reflective trim at calf and ankles.

Sizing

Jacket & Coat
Size Fits Chest Size Actual Chest Size Sleeve Length Jacket Lenght
Small 36-38" 46" 33" 29"
Medium 40-42" 50" 33.5" 29"
Large 44-46" 54" 34" 29"
X Large 48-50" 58" 34.5" 29"
2XL 52-54" 62" 35" 29"
3XL 56-58" 66" 35.5" 29"
4XL 60-62" 70" 36" 29"
5XL 64-66" 74" 36.5" 29"
Bib Trouser & Waist Pant
Size Fits Waist Size Actual Overall Waist Inseam Length
Small 32-34" 42" 29"
Medium 36-38" 46" 29"
Large 40-42" 50" 29"
X Large 44-46" 54" 29"
2XL 48-50" 58" 29"
3XL 52-54" 62" 29"
4XL 56-58" 66" 29"
5XL 60-62" 70" 29"

Sizes M-5XL are available in Longs and Talls. Longs have 2 inches added to the jacket length, sleeves and bib-trouser or waist pant inseam. Talls have 4 inches added to the jacket length, sleeves and bib-overall inseam.

Additional Info

Additional Info

Model MS-OMEGA-
Set Product as New to Date No
Usually Ships 3 to 7 days
Country of Origin USA
Manufacturer Warranty Yes
Select Size No
Standards High Visibility: ANSI 107
Flash Fire: ASTM F2733
ASTM E96 & F1868
Electric Arc: ASTM F1891 & NFPA 70E
Mfr. Model # No
Specification No
Manufacturer No

Reviews

Write Your Own Review

You're reviewing: Omega Arc Flash Waterproof Hi-Vis Rainwear

Tags

Tags

Use spaces to separate tags. Use single quotes (') for phrases.

NFPA 70E Training

Any doubts that your company is compliant? Your employees safe?

The 2015 Edition of the NFPA 70E recommendations are in print and take effect January 1, 2015.

Do you and your employees know all of the changes? Have they been implemented into your Electrical Safety Program? Do you have an Electrical Safety Program? Have you had Electrical Safety Training in the last year?

Electrical Safety Compliance Chart for NFPA 70E 2015

If the answer to any of those questions is no, then contact Macron Safety today!

Call 916-905-6535 or contact us to be certain you are in compliance.

Determine the Correct Protection Level, To evaluate Fire Retardant clothing materials in order to measure the heat transferred through the fabric, two values are calculated: Arc Thermal Performance Value (ATPV)...the minimum energy causing the predicted onset of second-degree burns and Heat Attenuation Factor (HAF)...the percentage of total energy of the arc that the fabric prevents from passing through, OSHA requires that each employer must assess the potential hazards in the work environment and determine the appropriate clothing materials using ASTM PS57-97. Always do a hazard assessment. You will need to know electrical system voltage, fault current available, number of phases, Arc time duration, estimated Arc gap, minimum distance from the Arc, and Arc configuration.

Free Duke Power Heat Flux Calculator: For the purpose of calculating heat flux received at a surface some distance from an Electric Arc.