Call 1 (916) 905-6535

Oberon 42 cal/cm² Protera Coat & Bib-Overall Suit LCI4

Be the first to review this product

Oberon's 42 cal/cm² Coat & Bib-Overall Suit - Hazard Risk Category 4 (HRC 4) 16 oz/yd² is made from Arc Flash Resistant, DuPont™ Protera™ sewn with Nomex™ thread. Meets current ASTM F1506-02ae1 and NFPA 70E-2012 and CSA Z462 standards.


The Coat & Bib-Overall Style kit Includes: Choice of size Coat & Bib-Overall & Arc Flash Hood.

Availability: In stock

$650.00

* Required Fields

Oberon

Description

Details

made in the USA

The Coat & Bib-Overall protects from Arc Flash heat exposure / Electric Arc hazards and is constructed of materials that are Inherently FR (Flame Resistant). It will remain Flame Resistant after years of frequent & repeated laundering. This means that the FR protection won't wash or wear away. Manufactured with an Inherently Flame Resistant Modacrylic blend. All fibers used in the construction of these garments are Inherently Flame-Resistant, including the thread.The protective Coat & Bib-Overall are manufactured with DuPont™ Protera™ fabric. The fabric is durable and comfortable and meets NFPA 70E, ASTM F1506-02ae1, CSA Z462-08 requirements.

  • 16 oz/yd² fabric has an Arc Rating of 42 cal/cm² ATPV.
  • Hazard Risk Category 4.
  • Wrists and front closures with a Nomex Velcro® safety flap.
  • Constructed with Flame Resistant Suspenders.
  • Wide Pant Legs that are easy to slide on over work boots, equipped with Velcro cinch straps.
  • Sewn with Flame-Resistant thread.
  • Meets NFPA 70E-2012 and ASTM F-1506-02ae1.
  • Note: Personal protective equipment should be chosen to meet or exceed the expected incident energy at a specific work site.

The Faceshield window is manufactured with Oberon's proprietary ArcX™ energy absorbing polycarbonate material. The Faceshield window of the 42 cal/cm² Faceshield offers a Visible Light Transmission (VLT) of 52%. The shield's outer surface is manufactured with Oberon's proprietary material Silicote™-1 scratch resistant coating, for longer product life, and the inner surface manufactured with a permanent anti-fog coating, for increased visibility. Meets ANSI Z87.1 requirements.

42 calorie Arc Flash Hood with Ventilation System

These Hoods circulate fresh cool air inside the Hood to keep workers cool and comfortable in hot situations. Removable, replaceable vent fans and battery pack will provide 9 hours of continuous operation. Designed for worker comfort and reliability.

LCI Series Inherently FR Modacrylic Blend

LCI Series of arc flash garments are manufactured from Inherently FR Dupont Protera fabric. Dupont Protera was developed as an alternative to FR Treated Cotton blends. This fabric requires no special laundering care.

Coveralls and Bib-Overalls feature ankles with Nomex® Velcro® hook and loop straps. Coats and Coveralls feature wrists and front closures with Nomex® Velcro safety flap. Hood Windows and faceshields are manufactured with Oberon’s proprietary ArcXTM energy absorbing polycarbonate plastic. Our shields provide superior Visible Light Trans- mission (VLT) and have scratch resistant coating on the outer surface (for longer product life) and antifog coating on the inner surface (for improved visibility).

Any doubts that your company is compliant? Your employees safe?

The 2012 Edition of the NFPA 70E recommendations are in print and take effect January 1, 2012.

Do you and your employees know all of the changes? Have they been implemented into your Electrical Safety Program? Do you have an Electrical Safety Program? Have you had Electrical Safety Training in the last year?

If the answer to any of those questions is no, then contact Macron Safety today!

Call 916-905-6535 or contact us to be certain you are in compliance.

Determine the Correct Protection Level

To evaluate Fire Retardant clothing materials in order to measure the heat transferred through the fabric, two values are calculated: Arc Thermal Performance Value (ATPV)...the minimum energy causing the predicted onset of second-degree burns and Heat Attenuation Factor (HAF)...the percentage of total energy of the arc that the fabric prevents from passing through, OSHA requires that each employer must assess the potential hazards in the work environment and determine the appropriate clothing materials using ASTM PS57-97. Always do a hazard assessment. You will need to know electrical system voltage, fault current available, number of phases, Arc time duration, estimated Arc gap, minimum distance from the Arc, and Arc configuration.

Free Duke Power Heat Flux Calculator: For the purpose of calculating heat flux received at a surface some distance from an Electric Arc.

Electrical Safety Compliance Chart for NFPA 70E 2012

Additional Info

Additional Info

Model MS-LCI4B
Set Product as New to Date No
Usually Ships 10 to 14 days
Country of Origin USA
Manufacturer Warranty 1 Year
Specification
Part Number Size Style Color
MS-LCI4B-S Small 42 cal Coat & Bib Overall w/ 42 cal/cm² Arc Flash Hood w/ Hard Cap - HRC 4 Navy Blue
MS-LCI4B-M Medium 42 cal Coat & Bib Overall w/ 42 cal/cm² Arc Flash Hood w/ Hard Cap - HRC 4 Navy Blue
MS-LCI4B-L Large 42 cal Coat & Bib Overall w/ 42 cal/cm² Arc Flash Hood w/ Hard Cap - HRC 4 Navy Blue
MS-LCI4B-XL X-Large 42 cal Coat & Bib Overall w/ 42 cal/cm² Arc Flash Hood w/ Hard Cap - HRC 4 Navy Blue
MS-LCI4B-2XL 2X-Large 42 cal Coat & Bib Overall w/ 42 cal/cm² Arc Flash Hood w/ Hard Cap - HRC 4 Navy Blue
MS-LCI4B-3XL 3X-Large 42 cal Coat & Bib Overall w/ 42 cal/cm² Arc Flash Hood w/ Hard Cap - HRC 4 Navy Blue
MS-LCI4B-4XL 4X-Large 42 cal Coat & Bib Overall w/ 42 cal/cm² Arc Flash Hood w/ Hard Cap - HRC 4 Navy Blue
MS-LCI4B-5XL 5X-Large 42 cal Coat & Bib Overall w/ 42 cal/cm² Arc Flash Hood w/ Hard Cap - HRC 4 Navy Blue
Part Number Size Style Color
MS-LCI4B-S+HVS Small 42 cal Coat & Bib Overall w/ 42 cal/cm² Arc Flash Hood w/ Hard Cap & Ventilation System - HRC 4 Navy Blue
MS-LCI4B-M+HVS Medium 42 cal Coat & Bib Overall w/ 42 cal/cm² Arc Flash Hood w/ Hard Cap & Ventilation System - HRC 4 Navy Blue
MS-LCI4B-L+HVS Large 42 cal Coat & Bib Overall w/ 42 cal/cm² Arc Flash Hood w/ Hard Cap & Ventilation System - HRC 4 Navy Blue
MS-LCI4B-XL+HVS X-Large 42 cal Coat & Bib Overall w/ 42 cal/cm² Arc Flash Hood w/ Hard Cap & Ventilation System - HRC 4 Navy Blue
MS-LCI4B-2XL+HVS 2X-Large 42 cal Coat & Bib Overall w/ 42 cal/cm² Arc Flash Hood w/ Hard Cap & Ventilation System - HRC 4 Navy Blue
MS-LCI4B-3XL+HVS 3X-Large 42 cal Coat & Bib Overall w/ 42 cal/cm² Arc Flash Hood w/ Hard Cap & Ventilation System - HRC 4 Navy Blue
MS-LCI4B-4XL+HVS 4X-Large 42 cal Coat & Bib Overall w/ 42 cal/cm² Arc Flash Hood w/ Hard Cap & Ventilation System - HRC 4 Navy Blue
MS-LCI4B-5XL+HVS 5X-Large 42 cal Coat & Bib Overall w/ 42 cal/cm² Arc Flash Hood w/ Hard Cap & Ventilation System - HRC 4 Navy Blue
Manufacturer Oberon

Reviews

Write Your Own Review

You're reviewing: Oberon 42 cal/cm² Protera Coat & Bib-Overall Suit LCI4

Tags

Tags

Other people marked this product with these tags:

Use spaces to separate tags. Use single quotes (') for phrases.

NFPA 70E Training

Any doubts that your company is compliant? Your employees safe?

The 2015 Edition of the NFPA 70E recommendations are in print and take effect January 1, 2015.

Do you and your employees know all of the changes? Have they been implemented into your Electrical Safety Program? Do you have an Electrical Safety Program? Have you had Electrical Safety Training in the last year?

Electrical Safety Compliance Chart for NFPA 70E 2015

If the answer to any of those questions is no, then contact Macron Safety today!

Call 916-905-6535 or contact us to be certain you are in compliance.

Determine the Correct Protection Level, To evaluate Fire Retardant clothing materials in order to measure the heat transferred through the fabric, two values are calculated: Arc Thermal Performance Value (ATPV)...the minimum energy causing the predicted onset of second-degree burns and Heat Attenuation Factor (HAF)...the percentage of total energy of the arc that the fabric prevents from passing through, OSHA requires that each employer must assess the potential hazards in the work environment and determine the appropriate clothing materials using ASTM PS57-97. Always do a hazard assessment. You will need to know electrical system voltage, fault current available, number of phases, Arc time duration, estimated Arc gap, minimum distance from the Arc, and Arc configuration.

Free Duke Power Heat Flux Calculator: For the purpose of calculating heat flux received at a surface some distance from an Electric Arc.